Hotel Guestroom HVAC Maintenance




One of the first things that most guests do when they check into a hotel is go the air conditioner unit and crank the temperature to as low as possible in the summer months. There is nothing more irresistible than the feeling you are getting something for nothing. Now, imagine the look on your guest’s face when the air conditioner fails to deliver. The poorly maintained or inoperable air conditioner has denied them the exquisite sensation of the much coveted “free lunch”.
The maintenance team at your hotel wants to avoid this scenario at all cost. However, what can you do to ensure this won’t occur? Luckily, by following just a few simple tips from this post you can easily reduce the likelihood of this happening. The first step for maintaining guestroom air conditioners is a routine schedule of basic maintenance items. On the top of the list for scheduled maintenance will be the cleaning of filters at a regular interval. The period between cleanings may vary based on your location. However, at minimum the filters must be cleaned every 90 days. The typical guestroom utilizes an air conditioning unit called a Portable Terminal Air Conditioner or PTAC. The PTAC is normally equipped with two permanent filters that are easily cleaned with hot soapy water. Some hotels may purchase extra filters and utilize an exchange system. Dirty filters are removed and fresh filters are installed by housekeeping staff as part of a monthly deep cleaning process.
Annually, the entire PTAC should be removed from the guestroom and cleaned thoroughly. This typically requires two people due to the weight and cumbersome handling of the PTAC. It may be prudent to bring a digital thermometer and record the operating temperature of the unit prior to the cleaning You may find it easier to use a small cart or furniture dolly to move your PTACs to the cleaning station. Once outside the cover should be removed and set aside for cleaning. Inspect all electrical wiring and look for any obvious signs of damage. Using a water hose begin washing the condensate tray and condenser coil areas. Avoid spraying directly on any exposed wiring and components. A professional grade coil cleaning solution should be applied and then rinsed thoroughly to remove any residue. Inspect all coils and fins for damage. A fin straightener should be used to repair any damaged areas. After the PTAC unit, cover and filters have been cleaned, utilize a condensate tray treatment to minimize odors and keep mold, mildew and algae from growing inside the condenser area.
When the PTAC has dried out return the unit to the guestroom. Ensure the PTAC is fully inserted into the wall sleeve and secured properly. Ensure that no gaps or openings are present that could allow air and unwanted pests to enter the room. The PTAC must be turned on and allowed to operate. Ensure the compressor turns on and the fan is not making any abnormal noises. Now, that your PTAC has been fully cleaned and running for a few minutes take a quick check on the operating temperature with your thermometer, it will be typically 10 to 15 degrees cooler than an uncleaned air conditioner. You will find that an annual cleaning of condenser coils can dramatically improve the efficiency of an air conditioner. The guests will appreciate a quietly operating air conditioner delivering a sinfully large amount of “free” cold air.


No comments:

Post a Comment